Barrow Logo Barrow EP Handbook

Reading a PCA report

A Property Condition Report is long, and most readers go straight to the cost tables. Fine, but five other places reward attention.

The scope and deviations section. E2018 requires the report to present material deviations from the guide and any services beyond the baseline. This is where you learn what this particular PCA actually was: what was excluded, what could not be accessed, what the consultant did that a baseline would not include.

Condition language. Reports characterize systems with rating vocabulary (good, fair, poor, and variations), and the guide requires disparate conditions to be explained rather than averaged away. A "fair overall" roof with one failing section is a different fact from a uniformly fair roof; the narrative, not the rating, carries that.

The basis of the cost opinions. The guide lets consultants draw costs from published cost data, their own files, owner information, or user-provided figures, and says plainly that these are opinions, not bids and not exact quantities. Treat a PCR number as an order of magnitude for negotiation, then get contractor pricing for anything that matters to the deal.

Specialist recommendations. When the field observer flags something for a structural engineer, roofer, or elevator consultant, that is the report telling you its own limit. An un-followed specialist recommendation is an open question you are choosing to carry.

Interview and document gaps. What the consultant could not get, from drawings to maintenance records to a knowledgeable site contact, bounds what the report can know, the same way data gaps bound a Phase I.

Read that way, a PCR is less a verdict than a map of where the building's money questions live, and how confident anyone can be about each.