Barrow Logo Barrow EP Handbook Schedule a Demo

Triethylene glycol cleanup levels by state

  • CAS 112-27-6
  • 2 states

CAS 112-27-6 is in the cleanup-level tables of 2 states in this handbook: Pennsylvania (TRIETHYLENE GLYCOL) and Texas (Triethylene glycol). Each state's numbers are below as its agency prints them. The states run different programs and do not define their values the same way, so a number from one is not the same measure as a number from another. A state that lists the substance under another CAS number, or without one, is not shown here.

Pennsylvania

  • PA DEP
  • Act 2 Statewide Health Standards

For TRIETHYLENE GLYCOL, DEP's Statewide Health Standard tables print 69,000 μg/L for residential groundwater in a used aquifer with TDS up to 2500, 10,000 mg/kg for residential soil direct contact from 0 to 15 feet, and two residential soil to groundwater values for a used aquifer with TDS up to 2500: 6,900 mg/kg as 100 X GW MSC and 870 mg/kg as the generic value.

  • 69,000μg/L 69000 R Table 1: Medium-Specific Concentrations (MSCs) for Organic Regulated Substances in Groundwater Used Aquifers, TDS ≤ 2500
  • 10,000mg/kg 10000 0-15 feet Table 3a: Medium-Specific Concentrations (MSCs) for Organic Regulated Substances in Soil: A. Direct Contact Numeric Values Residential
  • 6,900mg/kg 6900 100 X GW MSC Table 3b: Medium-Specific Concentrations (MSCs) for Organic Regulated Substances in Soil: B. Soil to Groundwater Numeric Values Used Aquifers, TDS ≤ 2500, Residential
  • 870mg/kg Generic Value Table 3b: Medium-Specific Concentrations (MSCs) for Organic Regulated Substances in Soil: B. Soil to Groundwater Numeric Values Used Aquifers, TDS ≤ 2500, Residential

All Pennsylvania values for TRIETHYLENE GLYCOL

Texas

  • TCEQ
  • TRRP Tier 1 PCLs
  • February 6, 2025

For Triethylene glycol, TCEQ's Tier 1 table prints 130,000 mg/kg for TotSoilComb and 94 mg/kg for GWSoilIng (residential soil, 0.5 acre source area), and 49 mg/L for GWGWIng (residential groundwater).

  • 130,000mg/kg 1.3E+05 TotSoilComb Table 1: Tier 1 Residential Soil PCLs 0.5 acre source area
  • 94mg/kg 9.4E+01 GWSoilIng Table 1: Tier 1 Residential Soil PCLs 0.5 acre source area
  • 49mg/L 4.9E+01 GWGWIng Table 3: Tier 1 Groundwater PCLs - Residential and Commercial/Industrial Residential

All Texas values for Triethylene glycol

Each agency's own publication governs: its current table, or the published rule where the agency says so. This page is a reference copy and not a cleanup decision. Check each agency's page before relying on a value.

Source

Maintained by Barrow. General reference only, not legal or professional advice. Barrow is not affiliated with or endorsed by any government agency. See how Barrow drafts the report